Plastic Insulated Control Cables (CU/XLPE/STA/PVC)

Model NO.: CU/XLPE/PVC/STA/PVC-450/750KV 37X1.5
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE
Model: Control Cable
Brand: Zhongchao
Armoured or Copper Tape Screened Cable: Not Less Than 12 Times of The Cable Diameter
Trademark: CHONGCHAO
Transport Package: Heat Treated Wooden Drum
Specification: Iec, Bs, VDE
Origin: China
HS Code: 8544
Model NO.: CU/XLPE/PVC/STA/PVC-450/750KV 37X1.5
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, CE
Model: Control Cable
Brand: Zhongchao
Armoured or Copper Tape Screened Cable: Not Less Than 12 Times of The Cable Diameter
Trademark: CHONGCHAO
Transport Package: Heat Treated Wooden Drum
Specification: Iec, Bs, VDE
Origin: China
HS Code: 8544
Plastic insulated control cables
Application of standard
The product is manufactured according to the standards of GB/T9330-2008 , IEC60227 < Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V> and IEC60502 m=1.2kV) up to 30kV(Um=36kV)>. PVC insulated and sheathed control cable is suitable for the interconnection in controlling, signaling, protecting and measuring systems with rated voltages up to 0.6/1kV.
 
Operating characteristic
Rated power- frequency voltage U0/U:450/750V or 0.6/1kV.
Max. permissible continuous operating temperature of conductor: 70ºC.
The ambient temperature for cable installation: ≥0ºC. If the ambient temperature is lower than 0ºC, the cable should be preheated.
The bending radius of cables are recommended as follows:
Non-armoured cable: not less than 6 times of the cable diameter.
Armoured or copper tape screened cable: not less than 12 times of the cable diameter.
Screened flexible cable: not less than 6 times of the cable diameter.
 
Type of cable
Type Nominal cross-section of conductor mm²  
0.5 0.75 1.0 1.5 2.5 4 6 10  
Number of cores  
KVV,KYJV               KVVP,KYJVP - 2-61 2-14  2-10  
 
KVVP2,KYJVP2,KVVP3,KYJVP3 - 4-61 4-14 4-10  
KVV22,KYJV22     KVVP2-22,KYJVP2-22 - 7-61 4-61 4-14  4-10  
 
KVV32,KYJV32 - 19-61 7-61 4-14  4-10  
KVVR,KYJVR 4-61 -  -  
KVVRP,KYJVRP 4-61 4-48 - -  
 
Conductor structure, product types and DC resistance at 20ºC
Nominal cross section
 mm²
Conductor structure Maximum DC resistance at 20ºC Ω/km
Class Number/single wire nominal diameter  mm Untinned Tinned
0.5 3 160/0.20 39.0 40.1
0.75 1 1/0.97 24.5 24.8
0.75 2 7/0.37 24.5 24.8
0.75 3 24/0.20 26.0 26.7
1.0 1 1/1.13 18.1 18.2
1.0 2 7/0.43 18.1 18.2
1.0 3 32/0.20 19.5 20.0
1.5 1 1/1.38 12.1 12.2
1.5 2 7/0.52 12.1 12.2
1.5 3 30/0.25 13.3 13.7
2.5 1 1/1.78 7.41 7.56
2.5 2 7/0.68 7.41 7.56
2.5 3 50/0.25 7.98 8.21
4 1 1/2.25 4.16 4.70
4 2 7/0.85 4.16 4.70
6 1 1/2.76 3.08 3.11
6 2 7/1.04 3.08 3.11
10 2 7/1.35 1.83 1.84
Plastic insulated control cables
Application of standard
The product is manufactured according to the standards of GB/T9330-2008 , IEC60227 < Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V> and IEC60502 m=1.2kV) up to 30kV(Um=36kV)>. PVC insulated and sheathed control cable is suitable for the interconnection in controlling, signaling, protecting and measuring systems with rated voltages up to 0.6/1kV.
 
Operating characteristic
Rated power- frequency voltage U0/U:450/750V or 0.6/1kV.
Max. permissible continuous operating temperature of conductor: 70ºC.
The ambient temperature for cable installation: ≥0ºC. If the ambient temperature is lower than 0ºC, the cable should be preheated.
The bending radius of cables are recommended as follows:
Non-armoured cable: not less than 6 times of the cable diameter.
Armoured or copper tape screened cable: not less than 12 times of the cable diameter.
Screened flexible cable: not less than 6 times of the cable diameter.
 
Type of cable
Type Nominal cross-section of conductor mm²  
0.5 0.75 1.0 1.5 2.5 4 6 10  
Number of cores  
KVV,KYJV               KVVP,KYJVP - 2-61 2-14  2-10  
 
KVVP2,KYJVP2,KVVP3,KYJVP3 - 4-61 4-14 4-10  
KVV22,KYJV22     KVVP2-22,KYJVP2-22 - 7-61 4-61 4-14  4-10  
 
KVV32,KYJV32 - 19-61 7-61 4-14  4-10  
KVVR,KYJVR 4-61 -  -  
KVVRP,KYJVRP 4-61 4-48 - -  
 
Conductor structure, product types and DC resistance at 20ºC
Nominal cross section
 mm²
Conductor structure Maximum DC resistance at 20ºC Ω/km
Class Number/single wire nominal diameter  mm Untinned Tinned
0.5 3 160/0.20 39.0 40.1
0.75 1 1/0.97 24.5 24.8
0.75 2 7/0.37 24.5 24.8
0.75 3 24/0.20 26.0 26.7
1.0 1 1/1.13 18.1 18.2
1.0 2 7/0.43 18.1 18.2
1.0 3 32/0.20 19.5 20.0
1.5 1 1/1.38 12.1 12.2
1.5 2 7/0.52 12.1 12.2
1.5 3 30/0.25 13.3 13.7
2.5 1 1/1.78 7.41 7.56
2.5 2 7/0.68 7.41 7.56
2.5 3 50/0.25 7.98 8.21
4 1 1/2.25 4.16 4.70
4 2 7/0.85 4.16 4.70
6 1 1/2.76 3.08 3.11
6 2 7/1.04 3.08 3.11
10 2 7/1.35 1.83 1.84

Single USB Travel Plug

Single USB Travel Plug,Industrial Wall Mounted Socket Outlet,Australian Usb Power Wall Socket