Causes and Solutions of Ringing in Torque Motor Operation

During the use of the torque motor, sometimes we will find that after the motor is energized, the motor does not rotate but it continuously emits a squeaky sound. If the motor is not energized, it will inevitably lead to a sudden increase in motor temperature during long-time operation, and even motor failure will occur.

The reason why the motor does not turn with electricity after it is energized is that: the stator winding and the rotor winding have an open circuit (one-phase breakage) or the power supply loses power; the winding lead wire ends are connected incorrectly or the winding internal connection is reversed; the power supply circuit contacts Loose, large contact resistance; motor load is too large or the rotor is stuck; power supply voltage is too low; small motor assembly is too tight or grease inside the bearing is too hard;

The countermeasures for disengaging the torque motor from humming are: to find out which points of the stator and rotor have broken points to repair; to check the polarity of windings, determine whether the end of the winding is correct, and correct connection errors in a timely manner; tighten the loose connection screws and use a multimeter. Determine whether each connector is falsely connected and repair it; reduce the load or detect and eliminate mechanical failure; check whether the specified Δ connection method is incorrectly connected to Y, and correct; if the pressure drop is too large due to the power supply wire is too fine, correct it; Small motors are re-assembled to make them flexible when they are too tight; qualified grease is replaced when the grease is too hard; the bearing is stuck and repaired in time.

Dekos (TKS) transmission equipment http://professional production and sales of induction motor, speed control motor, reversible motor, electromagnetic brake motor, torque motor, small gear motor, brushless DC motor, brushless DC motor, planetary speed reduction Machine and so on.